The base isolation systems are gaining large attention as a mean to protect structure form seismic hazard. It is a suitable technology for earthquake resistant design of variety of structure like buildings, bridges, airport terminals, nuclear power plant etc. Seismic isolation consists of essentially the installation of mechanisms which decouple the structure from base by providing seismic isolators. The seismic isolation system is mounted beneath the superstructure and is referred as Base Isolation. The aim of this study deals with structural behavior of building with and without base isolation. Lead rubber bearing is used as an isolation device then compare various parameters like Base shear, Displacement, Storey drift. 5and 15 storey buildings are test models. Nonlinear time history analysis is carried out for both fix base and base isolated structure.

Key Words: Base isolation, Storey drift, Base shear, Nonlinear time history analysis, SAP2000

##plugins.themes.academic_pro.article.details##

Author Biographies

Numair A. Shaikh, M.S. Bidve Engineering College, Latur

PG Student M. E. (Structural Engineering), Civil Engineering Department

Dr. Ashok S. Kasnale, M.S. Bidve Engineering College, Latur

Professor Civil Engineering Department
How to Cite
Shaikh, N. A., & Kasnale, D. A. S. (2015). Seismic Performance for Fixed Base and Base Isolated Reinforced Concrete Structure. International Journal of Emerging Trends in Science and Technology, 2(04). Retrieved from https://ijetst.igmpublication.org/index.php/ijetst/article/view/597

References

1. S.M.Dhawade, “Comparative study for Seismic performance of base isolated & Fixed base RC frame structure”, International journal of civil engineering Research, vol.5., pp.183-190., 2014
2. N.Torunbalci, G.Ozpalnlar, “Earthquake Response analysis of mid-storey buildings Isolated with various seismic isolation Techniques”, 14th world conference on Earthquake Engineering, vol.Oct.12-17,
3. N.R.Chandak, “Effect of base isolation on the response of reinforced concrete Building”, Journal of civil engineering Research, vol. 3(4), pp. 135-142.2013.
4. "P. P. Thakare,O. R. Jaiswal" Comparative Study of Fixed Base and Base Isolated Building using Seismic Analysis".International Journal of Earth Sciences and Engineering ISSN 0974-5904, Volume 04, No 06 SPL, October 2011, pp 520-525
5. S.M. Wilkinson , R.A. Hiley,” A non-linear response history model for the seismic analysis of high-rise framed buildings” Computers and Structures 84 (2006) 318–329
6. P. C. Tsopelas, S. Nagarajaiah, M. C. Constantinouand A. M. Reinhorn “Nonlinear dynamic analysis of multiple building base isolated structures” computers and structures vol.50.No 1, pp.47-57,1994.
7. N.Naeim&J.M.Kelly, Design of Seismic Isolated Structures from Theory to Practice, The reference book, 1999.
8. PankajAgarwal& Manish Shrikhande, “Earthquake Resistant Design of Structures”, PHI Learning, New Delhi, 2010.
9. Anil K Chopra “Dynamics Of Structures theory and application to earthquake engineering ”Pearson Education Inc.
10. CSI Analysis Reference Manual for SAP2000®.